Apator

 

ASR pro Description   Thông số kỹ thuật Material   Feature
 ARS pro vertical fuse switch disconnectors
ARS pro vertical fuse switch disconnectors are designed for distribution of electricity and protection against short cir­cuits and overloads in three phase alternative current circuits. ARS pro fuse switch disconnectors are dedicated for applications which require reliability and safety like low voltage distribution boards installed in transformer substations, industrial low voltage distribution boards and cable cabinets.   ARS 00/100mm pro In=160 A, Un=690 V
ARS 00 pro In=160 A, Un=690 V
ARS 2 pro In=400 A, Un=690 V
ARS 3 pro In=630 A, Un=690 V
ARS 630 kVA pro In=910 A, Un=400 V
RWS 1250 A pro In=1250 A, Un=400 V
ARS 1250 A pro In=1250 A, Un=400 V
Lateral bus bar terminal
Electronic fuse monitoring module
ARS fuse switch disconnectors are made of fibre glass strengthened, thermoplastic polyamides with halogen free flame retardant added. Added flame retardant provides V2 flammability class according to IEC 60695-11-10. Such thermoplastics have longer self-extinguish time after ignition source is removed than V0 class thermoplastics. Also dripping of non fla­ming parts of plastic is allowed.  
  • parallelly moving, double contact system,
  • two arc chutes installed in each pole 2 are equipped with metal plates that stretch and further split electric arc during switching off of the circuit,
  • main base of fuse switch disconnector ARS pro is made of halogen free, fibre glass strengthened, self extingu­ishing, thermoset polyester of V0 flammability class,
  • other plastic parts of fuse switch disconnectors ARS pro are made of fibre glass strengthened, thermoplastic polyamides with halogen free flame retardant added; thanks to such addition the highest flammability class – V0 was achieved,
  • silver plated contacts provide low power loss and high conductivity,
  • for installation on to 185 mm busbar system,
  • triple pole switching (three poles at the same time) or single pole switching 

 

Apator

 

RA and RAB Description   Technical data Standard   Feature
 RAB with fuses
RA switch disconnectors and RAB switch disconnectors fuses are designed for distribution of electricity, making and breaking currents and protection of electrical equipment against shortcircuits and overloads in three phase alternative current circuits.   RAB 000, In=100 A
RAB 00, In=160 A
RAB 1, In=250 A
RAB 2, In=400 A
RAB 3, In=630 A
RA 100, In=100 A
RA 160, In=160 A
RA 250, In=250 A
RA 400, In=400 A
RA 630, In=630 A
RA 1250, In1250 A
Change-over switches I-0-II
Replacement for 400 a switch disconnector - RA 400/O
RIN switch disconnectors
RA are designed according to IEC/EN 60947-1, IEC/EN 60947-3 and can be used as main switch disconnector in distribution boards, switch disconnector, and switch disconnector for motor control and protection.   - safety of service and easy installation
- self-extinguishing thermoplastics (V0 flammability class)
- silver plated parts of current circuits
- self-tightening and self-cleaning contacts
- high electrical and mechanical endurance
- high short-circuit making and breaking capacity
- double, safe clearance between open contacts
- complete isolation of fuse links in „off” position
- manually operated drive (spring powered)
- wide range of accesories

 

Apator

 

RBK pro Description   Technical data Material   Feature
 RBK pro fuse disconnectors
RBK pro fuse switch disconnectors are designed for distribution of electricity and protection against short cir­cuits and overloads in three phase alternative current circuits. RBK pro fuse switch disconnectors are dedicated for applications which require reliability and safety like industrial low voltage distribution boards and cable cabinets.   RBK 00 pro In=160 A, Un=690
RBK 00 pro-V120 In=160 A, Un=690 V
RBK 1 pro In=250 A, Un=690 V
RBK 2 pro In=400 A, Un=690 V
RBK 3 In=630 A, Un=690 V
RBK 00-XT
RBK pro meet technical requirements of polish and other european electricity boards and are conforming to PN-EN 60947-1, PN-EN 60947-3,IEC 60947-1, IEC 60947-3 standards.
Fuse switch disconnectors RBK pro are made of plastic with the highest V0 flammability class according to IEC 60695-11-10. Fuse switch disconnectors made from such thermo­plastics self-extinguish in specified time after ignition source is removed. Also dripping of flaming parts of plastic does not occur.
 

- Triple pole switching,
- For installation on:
     - Mounting plate,
     - Double DIN rail with spacing of 125 mm or 150 mm,
     - On to 60 mm busbar system, top or bottom cable terminals,
- Arc chutes with steel deionization plates over top contacts,
- Possible cable connection: S-bridge clamp, M8 screw and V-

  shape clamp
- Possible sealing of a fuse switch disconnector,
- User can replace the fuse link while it is still hot after it  has

   operated, without touching it,

- Measuring holes to monitoring of the fuse state.

HOP THIEN COMPANY LIMITED

Address   : Ground Floor, Rosana Tower, No. 60 Nguyen Dinh Chieu St., Da Kao Ward, Dist. 1, Ho Chi Minh City, Vietnam
Tel

: +84 28 22 00 21 24 ; 09 88 57 43 47 (Mr. Trieu)

                                        09 79 87 84 50 (Mr. Khiet)            

Fax : +84 28 22 20 22 01
Email : thientrieu@hopthien.com
Website : http://www.hopthien.com


ngoxuantrieu

ngoxuantrieu

Joomla Templates - by Joomlage.com